Searchable abstracts of presentations at key conferences in endocrinology

ea0067gp44 | Poster Presentations | EYES2019

A rare cause of artifactual hypoglycemia

Mertens Jonathan , Haddad Maryam

Background: Glycemia point-of-care testing (POCT) is performed with fingerstick capillary whole-blood glucose measurement. These values correlate well with plasma glucose values. Hypoglycemia can be observed with POCT but should always be confirmed on plasma. True hypoglycemia must meet Whipple’s triad: signs/symptoms of hypoglycemia; low plasma glucose; improvement after glucose administration. Artifactual hypoglycemia is a discrepancy between POCT and plasma glucose and...

ea0064035 | CREST syndrome diagnosed because of faulty point-of-care glycaemia: a case report | BES2019

CREST syndrome diagnosed because of faulty point-of-care glycaemia: a case report

Jonathan Mertens , Maryam Haddad , Christophe de Block

Background: Glycaemia point-of-care testing (POCT) is performed with fingerstick capillary whole-blood glucose measurement. These values normally correlate well with plasma glucose values. Hypoglycemia can be observed with POCT but should always be confirmed on plasma. True hypoglycemia must meet Whipple’s triad: signs/symptoms of hypoglycemia; low plasma glucose; improvement after glucose administration. Artifactual hypoglycemia is defined as a discrepancy between POCT a...